Standard Electromagnetic Vibrator, KD-9363-EM
KD-9363-EM
Standard Electromagnetic Vibrator
KD-9363
推理值
Force(kgF)频率范围
Usable Freq Range(Hz)动圈重量
Mass of Armature(kg)动圈直径
Armature Diameter(mm)加速度
Sine Peak Acc(g)位移
Max Disp(mm)载重
Load Support Capacity(kg)冷却方式
Cooling Method
Obtained the award of excellent product design in 2001.
ROC Patent New-type 091293
Electromagnetic Shaker
- Coil structure earns Taiwan & USA patents.
Vibrator body is by air-bellow damping design; body’s natural frequency won’t influence floor structure or interfered by external vibration source.
Vibrator is by dual magnetic circuit’s design; the high magnetic alloy and H/APTZ-level coil can generate the best magnetic effort. The body & coil cooling system follows cooling airflow design that can ensure system’s stability.
The overall system is made by gravity casting; beautiful shape and strong; the bottom & side plates are made of spherical graphite cast steel, firm and with a low resonance frequency.
Slip Table
- Low-noise direct-connecting pump
Hydraulic pressure regulator and gauge indicator
Pressure-error indication and alarm
Air-bellow dampers x 6
System is designed at 3~5 Hz low resonance frequency; not influence floor structure.
Class A Granite platform / linear hydraulic pump
Slip table is made of Mg/Al alloy and military-standard super-hard anodizing; the surface hardness exceeds HR C60 & HV400.
Precise linear ball guider; no lateral vibration.
TEST TABLE
Mg/al die cast alloy
Table is made of aluminum alloy and military-standard super-hard anodizing
Horizontal Turntable Mechanism
- Free from bolting; save time; worm-linked gear mechanism; labor-saving
Automatic positioning bolt; wheel braking device, no sliding danger.
Servo System Protection
- Over displacement; over current; coil temperature error indication; power amplifier
Temperature error and exhaust fan error indications, amplifier N.TR/P.TR error indication and emergency stop indication; 10 error-digits indicator.
Power Amplifier
- Power efficiency: 96% (save several hundred thousand NTD per year and reduce massive hot air exhausted; save air conditioning power expense and improve working environment.)
Accuracy is set at 0.1%
Can set over current, over voltage and noise detection/protection as well as many output limits.
The LASER USB vibrator control system leads the vibration test into a USB 2.0 era. In the vibration controller field it first applies the new generation’s transmission interface. The control software has accepted the opinions from many R&D and production engineers, which makes the LASER USB vibrator control system more close to the four demands that operator concerns most: Convenience, high-performance, flexibility and security.
- Can extend to 16 input channels at most.
USB 2.0 transmission interface
Windows 2000/XP
Vibration control functions--sinusoidal sweep, random wave vibration, classical shock wave and other hybrid and more complex control functions.
24-bit resolution
ICP