The purpose of the bump tester is mainly to understand the degree of damage and specific functional degradation of the specimen, when it encounters a repetitive mechanical impact environment, It can also be used to evaluate the structural integrity.
This test is designed to simulate recurring impact effects that equipment and components may encounter during use and transportation, The test is mainly performed on test pieces that are unpackaged or packed in cartons. If it is the latter, it must be performed together with the carton.
During test, the test piece usually fixed on the fixture or on the impact machine test platform , the test is performed with a reproduced half-sine wave, The number of half-sine wave repetitions, wave acceleration and duration are set according to relevant specifications.
Functions Description
- Comply with IEC-68-2-29 testing specification (10g/ 16ms, 15g/6ms, 40g/6ms, 100g/2ms …..).
- Easy installation and simple operation, Low noise , no maintenance required.
- Design with very low resonant-structure , anti-vibration by air bag to effectively isolate floor vibration.
- Adjustable half-sine wave generator , easy adjust with high precision.
- Alloy platform design , Servo motor cam drive and adjustable of test speed.
- Patent design of adjustable acceleration value and shock duration.
Model
KD1319-30
KD1319-40
KD1319-60
KD1319-80
KD1319-100
KD1319-120
KD1319-130
KD1319-150
Table Dimension (cm)
30 x 30
40 x 40
60 x 60
80 x 80
100 x 100
120 x 120
130 x 130
150 x 150
Table Matrix Holes
Pith:50 mm with M8
Pith:100 mm with M10
Pith:100 mm with M12
Max. Load (kg)
30
50
100
150
200
200
600
1000
Min. Duration (ms)
1
1
2
3
5
5
6
6
Min. Duration (ms)
30
30
30
30
30
30
30
30
Test Speed (time/min)
Up to 120
Max. Velocity Change rate (m/s)
Wave
Half Sine
System Weight (kg)
480
900
1100
1600
2050
2920
6200
6500
System Dimension (mm)
W
720
920
1020
1120
1220
1514
1690
1690
D
600
788
888
900
1088
1334
1520
1520
H
777
913
1009
1068
1058
1260
1250
1338
Controller
Human Interface; Dimension: 430(W) x 430 (D) x1169 (H) mm
Power Requirement
AC 220V or 380V 50/60Hz