The display mode, operating functions, message & program setting and height control are under humanized design; excellent repeatability; high accuracy; software is easy to operate with and time saving in personnel training.
Test data & waveform can be saved, transferred to report and printed out.
Follow requirement to select tester type & standard; offer customerized design case.
Testers & related mechanisms are patented; precise movement without error.
Specially designed air bellow and vibration-attenuated seat can effectively absorb any natural displacement arisen during test; no anchor or footing device required.
High reliability; easy to maintain.
Wave: half-sine, square or saw-tooth wave
Measuring channel: standard four channels
Features:
Apply free-drop model; precisely simulate the actual environment.
Perform solid shock impact; no second rotating or displacing problem.
Full digitizing control system offers high efficiency.
Speed range is wide
Fast in changing wave model.
Comply with all commercial & military test specs.
Patented Braking System | Shock Amplifier |
Model No. | Gravity type Simple type |
Gravity type Basic type |
Gravity type Standard type | ||
Model | DP-1200-25-S100 | DP-1200-25-S | DP-1200-25-B100 | DP-1200-25-B | DP-1200-25 |
Table Size | 250 | 250 | 250 | ||
Control & Display Method | Manually set ascending height; no acceleration or waveform display. | Manually set ascending height; LED display of acceleration and run time. | Use PC software to control/display waveform. | ||
Peak acceleration g | 300 | 650 | 350 | 650 | 650 |
Peak stroke mm | 1000 | 1800 | 1000 | 1800 | 1800 |
Peak speed variation m/sec | 3.4 | 7.4 | 3.4 | 7.4 | 7.4 |
Peak load kg | 50 | ||||
Braking method | Simple Air Braking | Simple Air Braking | Standard Braking | ||
Minimum shock time domainmS | 1 | ||||
Outline dimensioncm | 85*60*210 | 85*60*310 | 85*60*210 | 85*60*310 | 85*60*310 |
Table material | Ma Alloy | ||||
Electrical requirement | 220V / 15A /3Ø | ||||
Air pressure requirement | 6 |
Model No. | Gravity type Standard type 2mS |
Gravity type Standard type 3mS |
Gravity type Standard type 2mS |
Gravity type Standard type 3mS |
Gravity type Standard type |
Gravity type Standard type |
Model | DP-1200-45 | DP-1200-45 | DP-1200-60 | DP-1200-60 | DP-1200-80 | DP-1200-100 |
Table Size | 450 | 450 | 600 | 600 | 800 | 1000 |
Control & Display Method | Use PC software to control/display waveform. | |||||
Peak acceleration g | 500 | 350 | 300 | |||
Peak stroke mm | 1800 | |||||
Peak speed variation m/sec | 7.4 | |||||
Peak load kg | 70 | 90 | 105 | 200 | ||
Braking method | Standard Braking | |||||
Minimum shock time domainmS | 2 | 3 | 2 | 3 | 3 | 3 |
Outline dimensioncm | 107*75*310 | 145*90*310 | 145*110*310 | 145*180*310 | ||
Table material | Ma Alloy | |||||
Electrical requirement |
220V / 20A /3Ø | |||||
Air pressure requirement | 6 |