Laboratory

Dongguan Lab

Dongguan LAB

Service Item

Location

1.Vibration test
2.Shock test
3.Drop test
No.5, Xiangnan 4th Street, Huangjiang Township, Dongguan,
Guangdong 523750, China
TEL:+86 769 8351 6866
FAX:+86 769 8351 6000
Map: (click to enlarge it)
廣東東莞所在位置

EM High Frequency Vibrating Tester

Show Details









Model No. EM-2000F2K-50N250 EM-1000F2K-50N250 EM-400F3K-30N80
Type of vibration sinusoidal, random, impact simulation sinusoidal, random, impact simulation sinusoidal, random, impact simulation
Frequency range 1~2000 Hz 1~2000 Hz 1~2000 Hz
Maximum acceleration 100 g(No Payload) 66 g(No Payload) 40 g(No Payload)
Maximum displacement 50 mm 50 mm 30 mm
Maximum load 500 kg 250 kg 80 kg
Maximum size of test object 1,400 mm × 1,200 mm 750 mm × 750 mm 600 mm × 600 mm
Test direction vertical and horizontal vertical and horizontal vertical

Shock Tester

Show Details

Model No. DP-1200-80 DP-1200-18
Executable waves half sine wave, square wave, saw-tooth wave half sine wave, square wave, saw-tooth wave
Measurable channels 4 channels (1 for control +3 for measurement) 4 channels (1 for control +3 for measurement)
Table size 800 × 1,000 mm 180 × 180 mm
Peak acceleration 500 g (accommodate the impact amplifier the peak acceleration can be up to 3000g) 1,500 g
Measuring software TP-3、DAS-105 TP-3、DAS-105

Packaged drop tester-KD-128A

Show Details

Model No. KD-128A
Swing arm type Single arm
Executable fall height 300 ~ 1300 mm
Maximum test load 80 kg
Maximum test volume 1400(w) × 600(d) mm
Buffer means Hydraulic buffer
Control means Wire control

Large Object Drop Tester KD-500

Show Details

Model No. KD-500
Swing arm type Multi-arm type
Executable fall height 10~800mm
Maximum test load 300 kg
Maximum test volume 1300(w) × 1150(d) mm
Buffer means Hydraulic buffer
Control means Wire control, PLC circuit control

Constant Temperature & Humidity Tester TMJ-9712

Show Details

Model No. TMJ-9712
Maximum temperature change rate 1℃/min
Maximum volume 1,000 × 1,000 × 1,000 mm
High temperature 100 ℃
Low temperature -40 ℃
Humidity 10% ~ 95% RH

Thermal Shock TesterTMJ-9709

Show Details

Mode No. TMJ-9709
Maximum temperature change rate 5-minute average temperature
Maximum volume 500 × 400 × 400 mm
High temperature 150 ℃
Low temperature -50 ℃
Executable specification CHS,MIL,IEC,JIA and other international standards